Surfaces
Overlays
Routing
Display
Smooth-scroll utilities like Mac Mouse Fix make a mouse look exactly like a trackpad to the browser, so auto-detect can't tell them apart — pick Always zoom there. Pinch always zooms and right-drag always pans, whatever you choose. Saved per device.
Orientation Tags
South Wall
🔒 Telco Board
👁
Grounding Bar / IBT
👁
Duplex Outlet
👁
🔒 Unistrut 1-5/8"
👁
🔒 Unistrut 1-5/8" (copy)
👁
🔒 Unistrut 1-5/8" (copy)
👁
Duplex Outlet (copy)
👁
North Wall
🔒 Security Board
👁
West Wall
Fire Alarm Panel
👁
Annunciator
👁
🔒 CLP
👁
🔒 Drivers 1
👁
🔒 Drivers 1 (copy)
👁
Unistrut 10ft
👁
East Wall (hidden)
🔒 INVERTER
👁
🔒 Panel M
👁
🔒 Panel H
800A
👁
🔒 Panel L
👁
🔒 Panel S
👁
🔒 Panel R
👁
Floor/Center (hidden)
Network Rack
👁
Network Rack (copy)
👁
Add Equipment
Room Dimensions
ft in
ft in
ft in
ft in
Entry Door
ft in
ft in
ft in
from center
Show Swing Arc
Wall Center Lines
Red Line (per wall)
ft in
ft in
ft in
ft in
New Conduit Run
EMT 2" — 4 pts
👁
New Conduit Run
EMT 4" — 3 pts
👁
New Conduit Run
EMT 4" — 3 pts
○
Save Current Project
Saved Projects
Share / Backup

Export saves your current project as a .json file. Import loads a previously exported project.

◀
▶
Left drag: orbit  |  Right drag: pan  |  Scroll: zoom  |  Click: select  |  Double-click: properties
Unistrut 10ft  X:0" Bot AFF:9'-4³⁄₁₆" 1" snap
Properties
⊹
Select an object to edit its properties.
Use + to add equipment
or ≋ to add a conduit run.
View: ISO │ Sel: None │ Cam: — conduitmap v2.0
⚡ NEC / CEC Code Check
Disclaimer: This tool provides general guidance based on NEC®/CEC code references and is intended for planning purposes only. It does not replace a licensed electrician, engineer, or Authority Having Jurisdiction (AHJ). Always verify compliance with your local codes and project specifications. ConduitMap assumes no liability for code violations or installation errors.
Add Equipment
Pick a Model to prefill typical dimensions, or Generic to size it yourself — then verify against the submittal and flip ★ Dims Verified.
Equipment is placed at the first open spot on the selected wall.
Drag to reposition  ·  Arrow keys for fine adjust  ·  Alt+drag to duplicate
Edit size, color, and all properties in the Properties panel after placing.
⚡ Room Starter
Gear lands in single-line order along the service wall — service gear, then subpanels, then the transformer with its low-voltage panel right after it — with 6" between enclosures so feeders and nipples pipe together cleanly. Overflow continues around the corner. Every spot is checked against working clearances (NEC 110.26), the door swing, and each other.
Everything is normal equipment afterward — drag, edit, or delete like anything you placed by hand. One Undo removes the whole rough-in.
Add Conduit Run
Click Start Drawing then hover equipment to see knockout dots.
Larger conduit sizes show fewer, wider-spaced knockouts.
Green ● = available   Red ● = occupied/blocked
Snap to equipment knockouts at start & end. Enter / Esc to finish.

conduitmap — 3D Electrical Layout

Professional 3D electrical room layout tool for foremen, PMs, and field electricians. Design, route conduit, and print wall elevations — all in the browser.

Getting Started

Navigation

Shortcuts

Conduit Tool

Two ways to start a run

Drawing the route

After placement

Tips
  • Nipples between adjacent panels facing each other only need a start KO and an end KO — no bends, just two clicks
  • Large conduit (3"+) blocks adjacent knockout positions automatically — you'll see fewer available KOs on a busy panel
  • Color-code runs (Properties → Color) to group circuits visually — e.g. all branch in grey, all feeders in orange
  • Use the Conduit tab list to see every run with trade size and length — fastest way to find a specific feeder in a crowded room
  • Hide finished runs from Layers while drawing new ones to keep the view clean

Equipment Layout

Two ways to place equipment

After placement

Available categories

Panels, FACP, transformers, switchboards, meters, disconnects, racks, outlets, junction boxes, solar gear, batteries, unistrut, grounding bars, obstructions. All snap to the selected wall by default. Wall-mount offset can be tuned per-piece in the Properties panel (useful for unistrut standoff).

Tips
  • Lock a piece (Properties → Lock) to prevent accidental drag when routing conduit nearby
  • Hide individual pieces or whole walls from the Layers tab to clean up the view while routing
  • Use the Equipment tab list to see every piece grouped by wall — fastest way to find something in a crowded room
✓ Exported
conduitmap
3D Electrical Layout

Pick a project type, name it, and set the size — everything can be changed later in the Room tab.

⚡ Electrical Room
Indoor room — four walls, panels, conduit, clearances
🏠 Residential Exterior
One outside wall — solar, batteries, service equipment
Width
West ↔ East
ft in
Depth
North ↔ South
ft in
Height
Floor ↔ Ceiling
ft in
①Add equipment — Press E to place panels, FACPs, transformers, and more ②Route conduit — Press C to draw conduit between equipment knockouts ③Measure & print — Press M to measure, P to print wall elevations
Tips: Drag equipment to reposition · Alt+drag to duplicate · Arrow keys for fine adjust · Scroll to zoom into first-person view · Press ? anytime for full help
Room saved ✓
Add Obstruction
Obstructions mark areas where equipment cannot be placed.
Drag to reposition · Edit size in Properties · Conduit can still route past.
3D Snapshot

Captures a PNG image of the selected wall view. Automatically hides blocking layers, takes the shot, and restores everything instantly.

Plan View (Top Down)
AI Render Prompt — copy & paste with your snapshot